PRESSURE PULSATION DAMPING
On Typical Diaphragm Metering Pumps |
|
Simply, how it works: 1. Pressure measured at one place in a piping system can be seen approx. 1400 meters away, (o.87 miles away) one second later. That is to say the speed of pressure wave transfer is generally over 3,000 miles per hour. 2. As pressure goes so fast, a piece of pipe, say 15 meters long (approx. 50 ft), reflects it back to source in 0.02 seconds, or say at 50Hz. Another thought is that it will pass a 100 mm "T" branch in 0.00007 of a second! So a one connection damper on the T can not respond. 3. Frequencies from short lengths of system, must be addressed by flow through dampers.* |
![]() |
| *Flow through, dampers give: More Flow Fluctuation Smoothing as well, PLUS A. Pressure pulse interception B. Flushability in place C. Standardization All at a lower cost! |
|
|
If for some reason you really must not have these benefits, keep the lower cost, by using one connection and the other saves a "T" for Gauge, Drain, R.V., or Rupture Disk. |
|
Principles of pressure activity reduction - briefly: |
|
![]() |
|
|
Importance of Prefill: |
Installation options: For Best Results, small connection to system for constant flow, larger to the pump for peak flows. Not more than 10 pipe IDs long. |
![]() |
|
|
"Dampers that do - Flow goes through, |
|