The COST $$ of HOSE TUBE PUMPS
with Various PulseGuard DampenersGO TO General/Prices/Installation/etc. Pages Hose Pumps with Pulsation Dampeners
![]()
22 M3/Hr. (100 USGPM) heavy oxides slurry at only 1.5 meters / sec in a DN80mm line settles our and plugs the Dampener / Accumulator. The need is for flow-through constant agitation & lower connection cost.
160 in3 pulse volume from diaphragm reversal & 1,000 in3 - 16Lt. Acc., only reduced spike 30%3 pcs. CPVC Ts3" $102
1x3"Flg + 3" NPT $17
pipe coupling $5
6 Hrs prime, bondfit-up & Hydro $430
4.3 USG PVC Acc $1,136
Total $1,680
2 Ts and a flange were saved by using a accumulator safety block, to which the dampener face "O" seals and which provides for bracket mounting.
The straight line from pump to damper guts gave pressure peak clipping. 2" pipe gave 3M/s. velocity
The 720 in3, 4 connection dampener does more than the 16 Liter Accumulator; but as the path is not through t he dampener, stable pressure was not evident.1 pc. 3" socket T $32
3.75 Hrs. fitting prep. & Hydro $269
11.8 Lt. Damper c/w pipe base $1,248
Total $1,549
A (415 in3) 6.75 Liter (125 psi) 8.5 Bar 4 connection true flow through FLEXORBER LP dampener, provides continuous agitation, in place flushability, saves all 3 T pieces and out performs an accumulator more than twice its size - 2.9 Hrs. Fitting prep. & Hydro. $208
6.7 Lt. Flexorber LP $800
Total $1,008
Pressure travels 300 times faster than flow
So pulsation - flies straight past a "T"!
Because flow is so slow, there is time to flow up, come to a stop, and flow back down a "T" on the other hand, whatever the residual pressure pulsation level is, it will fly straight past a "T".
CONCLUSION:- With 300% greater efficiency, because flow fluctuations & pressure pulsation are forced to see the inside of PULSEGUARD PULSE DAMPENERS, are more compact vessels and DO MORE WORK FOR A LOWER COST
hence the saying:-
Dampers that do, flow goes through, BUT pressure pulsation is caught
DON'T FORGET! Thistakes you straight back to the beginning -- don't use back, back, back Explorer button.
PulseGuard
Dampeners the Do - Flow goes through, BUT Pressure pulsation does not.